1.A Railway Stations is provided for the following purpose
(a)To entrain or detrain the passengers
(b)To load or off load the goods or parcels
(c)To enable the faster trains to overtake the slower trains
(d)All the above*
Answer - (d)All the above*
2.For Category “A” stations, the annual passenger earning should be
(a)Rs. 10 crores of more
(b)Rs. 6 crores or more*
(c)Rs. 3 crores or more
(d)Less than Rs. 3 crores
Answer -(b)Rs. 6 crores or more*
3.Category “B” station are those, where annual passenger earnings are
(a) Rs. 6 to 10 crores
(b) Rs. 3 to 6 crores*
(c) Rs. 1 to 3 crores
(d) Less than Rs. 1 crore
4.The minimum essential facility at each type of stations A to F consist of
(a) Booking facility
(b) Drinking Water
(c) Waiting hall/shed
(d) All the above*
Answer -(d) All the above*
5.Numbers of taps on each platform of ‘A’ category station as per norms of minimum essential facility criteria are
(a) 6
(b) 8
(c) 12
(d) 15*
Answer -(d) 15*
6.Numbers of taps on each platform of ‘B’ category station as per norms of minimum essential facility criteria are
(a) 6
(b) 8
(c) 12*
(d) 15
Answer -(c) 12*
7.Numbers of taps on each platform of ‘C’ category station as per norms of minimum essential facility criteria are
(a) 6*
(b) 8
(c) 12
(d) 15
Answer -(a) 6*
8.Numbers of latrines on ‘A’ category of stations as per norms for essential amenities is
(a) 2
(b) 4
(c) 6
(d) 10*
Answer -(d) 10*
9.Numbers of latrines on ‘B’ category of stations as per norms for essential amenities is
(a) 2
(b) 4
(c) 6 *
(d) 10
Answer -(c) 6 *
10.Numbers of latrines on ‘C’ category of stations as per norms for essential amenities is
(a) 2 *
(b) 4
(c) 6
(d) 10
Answer - (a) 2 *
11.Numbers of latrines on ‘D’ category of stations as per norms for essential amenities is
(a) 2
(b) 4*
(c) 6
(d) 10
Answer -(b) 4*
12.A model stations on railways should have
(a) Minimum essential facilities
(b) Desirable facilities*
(c) Recommended facilities
(d) All the above
Answer -(b) Desirable facilities*
13.For ‘A’ category stations it is necessary to provide
(a) High level platform*
(b)Medium level platform
(c) Rail level platform
(d) All the above
Answer -(a) High level platform*
14.For ‘B’ category stations as per minimum essential facility it is necessary to provide
(a) High level platform
(b) Medium level platform*
(c) Rail level platform
(d) All the above
Answer -(b) Medium level platform*
15.Foot over bridge must be provided on the following type of stations as per minimum essential facility criteria
(a) A, B, C, & D class station
(b) A,B & C class station*
(c) A, & B class station
(d) Only A class station
Answer - (b) A,B & C class station*
16.Latrines & urinals must be provided on these type of stations as per minimum essential facility criteria
(a) A, B, C, D, E & F type station
(b) A,B,C,D & E type station*
(c) A,B,C & D type station
(d) A, B & C type station
Answer - (b) A,B,C,D & E type station*
17.Number of taps to be provided on ‘A’ category stations on each platform as per norms of minimum essential facilities are
(a) 20 taps
(b) 15 taps
(c) 12 taps*
(d) One taps for each bogie
Answer -(c) 12 taps*
18.Number of urinals & latrines to be provided on ‘A’ category stations as per norms on main essential facilities are
(a) 15
(b) 10*
(c) 8
(d) 6
Answer -(b) 10*
19.Urinals & Latrines for A & B stations as norms for recommended level of facilities for railway station
(a) Ndb/500
(b) Ndb/300
(c) Ndb/200*
(d) None of the above
Answer -(c) Ndb/200*
20.Number of taps on platform as per norms for recommended level of facilities
(a) One for every coach
(b) One for alternate coach*
(c) One every 200 metres distance
(d) At the discretion of DRM
Answer -(b) One for alternate coach*
21.Which of the facilities do not exist at halt station?
(a) Facilities for stopping the train
(b) Facilities for a small waiting
(c) Facilities for crossing of train*
(d) Facilities for book of passengers
Answer -(c) Facilities for crossing of train*
22.Height of platform of a flag station in cutting above rail level is
(a) Same height as Rail level
(b) 305 mm above rail level
(c) 455 mm above rail level
(d) 840mm above rail level*
Answer -(d) 840mm above rail level*
23.Size of cubicle of a booking office is kept as
(a) 1.20 x 1.50 m
(b) 1.50 x 1.20 m
(c) 1.50 x 1.80 m
(d) 1.80 x 1.50 m*
Answer -(d) 1.80 x 1.50 m*
24.“B” class station is provided only on
(a) Single lines
(b) Double line
(c) On both single as well as double line*
(d) None of them
Answer -(c) On both single as well as double line*
25.Height of high level platform for passengers for BG is --- high
(a) 0.455 m
(b) 0.560 m
(c) 0.650 m
(d) 0.760 m*
Answer -(d) 0.760 m*
26.Height of Low level platform for passengers for BG is --- high
(a) 0.455 m*
(b) 0.560 m
(c) 0.650 m
(d) 0.760 m
Answer -(a) 0.455 m*
27.Number of model stations identified for development on Indian Railways is about
(a) 55
(b) 110*
(c) 265
(d) 320
Answer -(b) 110*
28.As per norms for desirable amenity as given to model station, the refreshment rooms should be provided on stations classified as ---
(a) A & B*
(b) A,B & C
(c) A,B,C & D
(d) A, B,C, D & E
(e) A
Answer -(a) A & B*
29.As per norms for desirable amenity as given to model station, the book stalls should be provided on stations classified as ---
(a) A & B
(b) A,B & C*
(c) A,B,C & D
(d) A, B,C, D & E
(e) A
Answer -(b) A,B & C*
30.As per norms for desirable amenity as given to model station, the public address system should be provided on stations classified as ---
(a) A & B
(b) A,B & C*
(c) A,B,C & D
(d) A, B,C, D & E
(e) A
Answer -(b) A,B & C*
31.As per norms for desirable amenity as given to model station, the parking facility/circulating area should be provided on stations classified as ---
(a) A & B
(b) A,B & C
(c) A,B,C & D*
(d) A, B,C, D & E
(e) A
Answer -(c) A,B,C & D*
32.As per norms for desirable amenity as given to model station, the water coolers should be provided on stations classified as ---
(a) A & B
(b) A,B & C
(c) A,B,C & D*
(d) A, B,C, D & E
(e) A
Answer -(c) A,B,C & D*
33.As per norms for desirable amenity as given to model station, the clock rooms should be provided on stations classified as ---
(a) A & B *
(b) A,B & C
(c) A,B,C & D
(d) A, B,C, D & E
(e) A
Answer -(a) A & B *
34.As per norms for desirable amenity as given to model station, the retiring rooms should be provided on stations classified as ---
(a) A & B*
(b) A,B & C
(c) A,B,C & D
(d) A, B,C, D & E
(e) A
Answer -(a) A & B*
35.Norms for No. of seats at recommended level at Cat. A stn. is
(a) 0.4 Ndb*
(b) 0.4 Nds
(c) 0.4 Nmax
(d) 100 on each P.F.
Answer - (a) 0.4 Ndb*
36.Norms for No. of seats at recommended level at Cat. B stn. is
(a) 0.4 Ndb *
(b) 0.4 Nds
(c) 0.4 Nmax
(d) 100 on each P.F.
Answer -(a) 0.4 Ndb *
37.Norms for No. of seats at recommended level at Cat. C stn. is
(a) 0.4 Ndb
(b) 0.4 Nds*
(c) 0.4 Nmax
(d) 100 on each P.F.
Answer -(b) 0.4 Nds*
38.Norms for No. of seats at recommended level at Cat. D stn. is
(a) 0.4 Ndb
(b) 0.4 Nds*
(c) 0.4 Nmax
(d) 100 on each P.F.
Answer -(b) 0.4 Nds*
39.Norms for No. of seats at recommended level at Cat. E stn. is
(a) 0.4 Ndb
(b) 0.4 Nds*
(c) 0.4 Nmax
(d) 100 on each P.F
Answer -(b) 0.4 Nds*
No comments: